Find the emission factors BuildingMinds uses to calculate the CO2 emissions in the following. For more information, on how carbon emissions are calculated, see Operational carbon emissions calculation.
All decimal numbers in this section are displayed with a decimal point.
All emission factors are in kgCO2 e/kWh.
All emission factors are in kgCO2 e/kWh.
0.202 kgCO2e/kWh (IPCC Emission Factor Database, “Natural gas”)
0.266 kgCO2e/kWh (IPCC Emission Factor Database, ‘Gas/Diesel oil‘).
Type | Value | Unit |
---|---|---|
Water supply | 0.344 | kgCO2 e/m3 |
Water disposal | 0.708 | kgCO2 e/m3 |
Type | Value | Unit |
---|---|---|
Incineration: hazardous | 21.294 | gCO2 e/kg |
Incineration: non-hazardous | 21.294 | gCO2 e/kg |
Landfill: hazardous | 8.902 | gCO2 e/kg |
Landfill: non-hazardous | 467.046 | gCO2 e/kg |
Other/Unknown: hazardous | 21.294 | gCO2 e/kg |
Other/Unknown: non-hazardous | 21.294 | gCO2 e/kg |
Recycling: hazardous | 21.294 | gCO2 e/kg |
Recycling: non-hazardous | 21.294 | gCO2 e/kg |
Reuse: hazardous | 21.294 | gCO2 e/kg |
Reuse: non-hazardous | 21.294 | gCO2 e/kg |
Waste to energy: hazardous | 21.294 | gCO2 e/kg |
Waste to energy: non-hazardous | 21.294 | gCO2 e/kg |
Type | Value | Unit |
---|---|---|
Bromomethane | Methyl bromide (CH3Br) | 2 | kgCO2 e/kg |
Methane (CH4) | 28 | kgCO2 e/kg |
Nitrogen trifluoride (NF3) | 16100 | kgCO2 e/kg |
Nitrous oxide (N2O) | 265 | kgCO2 e/kg |
R 114B2 | Halon-2402 | 1,2-Dibromotetrafluoroethane (C2Br2F4) | 1470 | kgCO2 e/kg |
R-10 | Carbon tetrachloride (CCl4) | 1730 | kgCO2 e/kg |
R-11 | CFC-11 | Trichlorofluoromethane (CCI3F) | 4660 | kgCO2 e/kg |
R-113 | CFC-113 | 1,1,2-Trichloro-1,2,2-trifluoroethane (C2CI3F3) | 5820 | kgCO2 e/kg |
R-114 | CFC-114 | Halon-242 | 1,2-Dichlorotetrafluoroethane (C2Cl2F4) | 8590 | kgCO2 e/kg |
R-115 | CFC-115 | Chloropentafluoroethane (C2ClF5) | 7670 | kgCO2 e/kg |
R-12 | CFC-12 | Dichlorofluoromethane (CCI2F2) | 10200 | kgCO2 e/kg |
R-123 | HCFC-123 | 2,2-Dichloro-1,1,1-trifluoroethane (C2Cl2F3) | 79 | kgCO2 e/kg |
R-124 | HCFC-124| 1-Chloro-1,2,2,2-tetrafluoroethane (C2ClF4) | 527 | kgCO2 e/kg |
R-125 | HFC-125 | | 3170 | kgCO2 e/kg |
R-12B1 | Halon-1211 | Bromochlorodifluoromethane (CBrCIF2) | 1750 | kgCO2 e/kg |
R-13 | CFC-13 | Chlorodifluoromethane (CCIF3) | 13900 | kgCO2 e/kg |
R-134 | HFC-134 | | 1120 | kgCO2 e/kg |
R-134a | HFC-134a | | 1300 | kgCO2 e/kg |
R-140a | 1,1,1- Trichloroethane | Methyl chloroform (C2H3Cl3) | 160 | kgCO2 e/kg |
R-141b | HCFC-141b |1,1,-Dichloro-1-1-fluoroethane (C2H3Cl2F) | 782 | kgCO2 e/kg |
R-142b | HCFC-142b | 1-Chloro-1,1,-difluoroethane (C2ClF2) | 1980 | kgCO2 e/kg |
R-143 | HFC-143 | | 328 | kgCO2 e/kg |
R-143a | HFC-143a | | 4800 | kgCO2 e/kg |
R-152 | HFC-152 | | 16 | kgCO2 e/kg |
R-152a | HFC-152a | | 138 | kgCO2 e/kg |
R-161 | HFC-161 | | 4 | kgCO2 e/kg |
R-21 | HCFC-21 | Dichlorofluoromethane (CHCl2F) | 148 | kgCO2 e/kg |
R-22 | HCFC-22 | Chlorodifluoromethane (CHClF2) | 1760 | kgCO2 e/kg |
R-225ca | HCFC-225ca | 3.3-dichloro-1,1,1,2,2-pentafluoropropane (C3HCl2F5) | 127 | kgCO2 e/kg |
R-225cb | HCFC-225cb | 1,3-Dichloro-1,1,2,2,3-pentafluoropropane (C3HCl2F5) | 525 | kgCO2 e/kg |
R-227ea | HFC-227ea | | 3350 | kgCO2 e/kg |
R-23 | HFC-23 | | 12400 | kgCO2 e/kg |
R-236cb | HFC-236cb | | 1210 | kgCO2 e/kg |
R-236ea | HFC-236ea | | 1330 | kgCO2 e/kg |
R-236fa | HFC-236fa | | 8060 | kgCO2 e/kg |
R-245ca | HFC-245ca | | 716 | kgCO2 e/kg |
R-245fa | HFC-245fa | | 858 | kgCO2 e/kg |
R-32 | HFC-32 | | 677 | kgCO2 e/kg |
R-365mfc | HFC-365mfc | | 804 | kgCO2 e/kg |
R-41 | HFC-41 | | 116 | kgCO2 e/kg |
R-43-10mee | HFC-43-10mee | | 1650 | kgCO2 e/kg |
R13 B1 | Halon-1301 | Bromotrifluoromethane (CBrF3) | 6290 | kgCO2 e/kg |
Sulfur hexafluoride (SF6) | 23500 | kgCO2 e/kg |